1. Before installing the trap , be sure to purge the pipeline with pressurized steam to remove debris from the pipeline.
2. A
filter should be installed in front of the trap to ensure that the trap is not blocked by the pipeline and clean the filter regularly .
3,
before and after the trap to install the valve, trap at any time convenient to pick up repair.
4. The condensate flow direction should be
consistent with the trap installation arrow mark.
5. The
trap should be installed at the low position of the equipment outlet, and the condensate should be discharged in time to avoid the steam resistance of the pipeline.
6. If there is no position to install the
trap at the lower position of the zui of the equipment, add a backwater bend (condensation water lifting joint) at the low position of the water outlet, and raise the condensed water level before installing the steam trap to avoid steam resistance.
7.
The outlet pipe of the trap should not be immersed in water. (If immersed in water, drill a hole in the bend to break the vacuum and prevent the sand from sucking back.)
8. Mechanical
traps should be installed horizontally.
9.
Steam traps should not be installed in series.
10. Each device should be fitted with a
trap .
11.
Before the thermostatic trap, more than one meter of non-insulated subcooling pipe is required. Other forms of trap should be as close as possible to the equipment.
12. When the drum type drying (with siphon type) equipment uses the
steam trap , please specify: use the steam trap with anti-steam resistance device to avoid the steam lock of the equipment.
13,
if the trap condensate recovery, the recovery should be above the trap outlet pipe manifold Explorer access, reducing the back pressure, to prevent backflow.
14.
If there is condensed water recovery after the trap , the pipelines with different pressure levels should be recycled separately.
15.
After the trap , the condensate recovery manifold cannot climb the slope, which will increase the back pressure of the trap .
16.
Install a check valve before the condensate from the trap enters the recovery manifold to prevent condensate from flowing back.
17. Install a
trap on the steam line . The main pipe should be provided with a condensate collecting well close to the radius of the main pipe, and then piped to the trap .
18, mechanical
traps are not used for a long time, you must remove the drain screw to drain the water inside to prevent freezing.
19, found that the
steam trap running steam, it is necessary to timely discharge and clean the filter, according to the actual use of the situation to check, in case of failure to repair at any time. At least one inspection per year is required to remove impurities.

The petri dish(Disposable Petri Dish), culture plate and elisa plate, all of them are made of high quality PS material. They are used for fungus, bacteria and other microorganism culture. The detachable Elisa plate is designed specially for ELISA. the whole strip is smooth and transparent without weld line on the bottom and the detachable plate, from 96well to 1 well can be randomly selected, greatly improving the flexibility of diagnosis and test. 


Common Features:

● Available in E.O. or Gamma radiation sterile.

● Available in individual or bulk pack.

● High strength carton package guarantees the transportation safety.



Culture Dish

Culture Dish,Disposable Culture Dish,Plastic Culture Dish,Sterile Culture Dish,Disposable Petri Dish

Hebei Orient Imp. & Exp. Co. Ltd. , https://www.orientmedcare.com